An internal relay is used to enable external ampliers when the
controller has powered up correctly and the system and application
software are ready. The amplier enable is a single pole solid state
relay with a normally open “contact”. The enable relay contact will
be open circuit if there is no power on the controller OR a following
error exists on a servo axis OR the user program sets it open with
the WDOG=OFF command.
ALL STEPPER AND SERVO AMPLIFIERS MUST BE INHIBITED WHEN
THE AMPLIFIER ENABLE OUTPUT IS OPEN CIRCUIT
ANALOGUE INPUT AIN0: 0 TO 10V
ANALOGUE OUTPUTS AOUT 0 TO AOUT 4
Output: +/-10V at 5mA
Output impedance: 100 Ohms.
Common 0V return. Isolated from I/O
& Encoders.
AMPLIFIER
ENABLE
(WATCHDOG)
RELAY OUTPUT
Amplier
Enable 1
Amplier
Enable 2
V+
V-
Trio Controller Servo Amplier
To other axis enables
24v 0v
0v
Enable
VIN +
VIN-
Vue de la page 4
1 2 3 4 5 6 7 8